長春市海洋光電有限公司
質(zhì)量保證,信譽第一!
咨詢電話

0431-89561560

網(wǎng)站公告:
長春市海洋光電有限公司是一個新型的集研發(fā),生產(chǎn),銷售為一體的高科技光電技術(shù)企業(yè)。
產(chǎn)品展示
0431-89561560
長春市高新區(qū)錦河街155號,中國·吉林東北亞文化創(chuàng)意科技園實驗樓3層303
產(chǎn)品展示Product

您當(dāng)前的位置: 首頁-產(chǎn)品展示-HR2000+ES 光譜儀

HR2000+ES 光譜儀

2019/08/07

  HR2000+ES High-resolution Spectrometer

  for Enhanced Sensitivity

  The HR2000+ES Spectrometer is a preconfigured system that integrates a high-resolution optical bench, a powerful 2-MHz analog-to-digital (A/D) converter, programmable electronics, a 2048-element CCD-array detector, and a high-speed USB 2.0 port. This innovative combination produces and extremely fast spectrometer and provides resolution to ~1.33 nm (FWHM).

  The HR2000+ES has a slightly larger entrance slit (10 microns) and an L2 quartz collection lens to allow for extended measurement applications including:

  Reflection (emissive and reflective color)

  Absorbance

  Irradiance

  Transmission

  The HR2000+ES allows users to capture and store a full spectrum into memory every millisecond (that's 1,000 full spectra every second) when the spectrometer is interfaced to a computer via a USB 2.0 port. The HR2000+ES is perfect for chemical, biochemical and other applications where fast reactions need to be monitored and fine spectral features need to be resolved.

  1,000 Full Spectra/Second

  Programmable Microcontroller

  High-resolution Applications

  HR2000+ES Sample Spectrum

  High-resolution "HR" Optical Bench

  Plug and Play Operation

  Configuration

  Pricing

  Specifications

  1,000 Full Spectra/Second

  The HR2000+ES utilizes an onboard, 2-MHz A/D converter, which allows you to capture and transfer one full spectrum into memory every millisecond when the spectrometer is interfaced to a PC via the USB port.

  Programmable Microcontroller

  The HR2000+ES has an onboard programmable microcontroller that provides flexibility in controlling the spectrometer and accessories. Through a new 30-pin connector, you can implement all operating parameters in the software, such as controlling external light sources, creating processes and routines and retrieving data from external devices. The HR2000+ES gives you access to 10 user-programmable digital I/Os for interfacing to other equipment; one analog input and one analog output; and a pulse generator for triggering other devices. (Programming the I/Os requires SpectraSuite Spectroscopy Operating Software.)

  High-resolution Applications

  The HR2000+ES is ideal for applications where fast reactions need to be monitored and high resolution is necessary, such as protein dynamics.

  HR2000+ES Sample Spectrum

  This power-up data for our LS-1 Tungsten Halogen Light Source was taken by an HR2000+ at 2-millisecond intervals. The graph shows the tremendous amount of data generated with the HR2000+s acquisition rate speed of 1000 spectra per second.

  High-resolution "HR" Optical Bench

  The exceptional ~1.33 nm optical resolution of the HR2000+ES is achieved by using the Ocean Optics High-resolution Optical Bench ?a 25.4-mm diameter, 101.6-mm focal length, symmetrical crossed Czerny-Turner optical design.

  Plug and Play Operation

  The HR2000+ES interfaces to a computer via USB 2.0 or RS-232 serial port. When using the serial port, the HR2000+ES requires a single 5-volt power supply (not included). Data unique to each spectrometer are programmed into a memory chip on the HR2000+; SpectraSuite Spectrometer Operating Software reads these values for easy setup and hot swapping among computers

Configuration

EquipmentDetails
SpectrometerHR2000+
GratingHC1
DetectorDET2B-200-1100
SlitSLIT-10
Collection LensL2

Pricing

ItemDescriptionPrice
HR2000+ESHR2000+ES User-configured Spectrometer. system. Includes SpectraSuite and an ASP.$6044

Specifications

Physical

Dimensions:148.6 mm x 104.8 mm x 45.1 mm
Weight:570 grams
Detector

Detector:

Sony ILX511B linear silicon CCD-array

Detector range:200-1100 nm

Pixels:

2048 pixels

Pixel size:

14 μm x 200 μm

Pixel well depth:

~62,500 electrons

Sensitivity:75 photons/count at 400 nm; 41 photons/count at 600 nm
Optical Bench
Design:f/4, Symmetrical crossed Czerny-Turner
Focal length:101.6 mm input and output
Entrance aperture:10 m wide slit
Grating:HC-1 provides 200-1100 nm range
Detector collection lens:L2
OFLV filter:OFLV 200-1100 nm
UV enhanced window:UV2
Fiber optic connector:SMA 905 to 0.22 numerical aperture single-strand optical fiber
Spectroscopic
Wavelength range:200-1100 nm (Grating dependent)
Optical resolution:~1.33-6.8 nm FWHM
Signal-to-noise ratio:250:1 (at full signal)
A/D resolution:14 bit
Dark noise:12 RMS counts
Dynamic range:2 x 10^8 (system); 1300:1 for a single acquisition
Integration time:1 ms to 65 s (20 s typical max.)
Stray light:<0.05% at 600 nm; <0.10% at 435 nm
Corrected linearity:>99.8%
Electronics
Power consumption:220 mA @ 5 VDC
Data transfer speed:Full scans to memory every 1 ms with USB 2.0 port, 15 ms with USB 1.1 port
Inputs/Outputs:Yes, 10 onboard digital user-programmable GPIOs
Analog channels:One 13-bit analog input; one 9-bit analog output
Auto nulling:No
Breakout box compatibility:Yes, HR4-BREAKOUT
Trigger modes:4 modes
Strobe functions:Yes
Gated delay feature:No
Connector:30-pin connector
Computer
Operating systems:Windows 98/Me/2000/XP, Mac OS X and Linux with USB port; Any 32-bit Windows OS with serial port
Computer interfaces:USB 2.0 @ 480 Mbps; RS-232 (2-wire) @ 115.2 K baud
Peripheral interfaces:SPI (3-wire); I2C inter-integrated circuit


網(wǎng)站首頁公司簡介產(chǎn)品展示行業(yè)資訊應(yīng)用中心售后服務(wù)在線留言聯(lián)系我們